Login
Register
Dark Mode
Brightness
Ambient Glow – Questions list
Register
Profile
Edit Profile
Messages
My favorites
My Updates
Logout
Recent questions tagged instrumentation-and-process-control
0
0 votes
0
0 answers
GATE Chemical 2019 | Question: 30
Consider two non-interacting tanks-in-series as shown in figure. Water enters $TANK$ $1$ at $q$ $cm^{3}/s$ and drains down to $TANK$ $2$ by gravity at a rate $k\sqrt{h_{1...
Arjun
5.1k
points
asked
Feb 24, 2019
Instrumentation and Process Control
gate2019
instrumentation-and-process-control
process-calculations-and-thermodynamics
numerical-answers
+
–
0
0 votes
0
0 answers
GATE Chemical 2019 | Question: 31
Choose the option that correctly matches the step response curve on the left with the appropriate transfer functions on the right. The step input change occurs at time $t...
Arjun
5.1k
points
asked
Feb 24, 2019
Instrumentation and Process Control
gate2019
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2017 | Question: 20
Match the variable in Group-$1$ with the instruments in Group-$2$.$\begin{array}{cc}\&\text{Group-$1$} & \text{Group-$2$} \\ &\text{P. Temperature} & \text{ I. Capacitanc...
Milicevic3306
8.0k
points
asked
Mar 26, 2018
Instrumentation and Process Control
gate2017
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2017 | Question: 21
An $LVDT$ (Linear Variable Differential Transformation) is a transducer used for convertingdisplacement to voltagevoltage to displacementresistance to voltagevoltage to c...
Milicevic3306
8.0k
points
asked
Mar 26, 2018
Instrumentation and Process Control
gate2017
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2017 | Question: 51
The open loop transfer function of a process with a proportional controller (gain $K_{C}$) is$$G_{OL}=K_{C}\frac{e^{-2s}}{s}$$Based on the Bode criterion for closed-loop ...
Milicevic3306
8.0k
points
asked
Mar 26, 2018
Instrumentation and Process Control
gate2017
numerical-answers
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2016 | Question: 17
Match the instruments in $Group–I$ with process variable in $Group–2$.$\begin{array}{cc}\\&\text{Group-1} & \text{Group-2} \\ &\text{P. Conductivity meter} & \text{ I. Fl...
Milicevic3306
8.0k
points
asked
Mar 26, 2018
Instrumentation and Process Control
gate2016
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2016 | Question: 18
What is the order of response exhibited by a $U$-tube manometer? Zero orderFirst orderSecond orderThird order
Milicevic3306
8.0k
points
asked
Mar 26, 2018
Instrumentation and Process Control
gate2016
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2016 | Question: 19
A system exhibits inverse response for a unit step change in the input. Which one of the following statement must necessarily be satisfied?The transfer function of the sy...
Milicevic3306
8.0k
points
asked
Mar 26, 2018
Instrumentation and Process Control
gate2016
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2016 | Question: 51
A liquid flows through an “equal percentage” valve at a rate of $2\:m^{3}/h$ when the valve is $10\%$ open. When the valve opens to $20\%$ the flowrate increases to $3\:m...
Milicevic3306
8.0k
points
asked
Mar 26, 2018
Instrumentation and Process Control
gate2016
numerical-answers
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2016 | Question: 52
A $PI$ controller with integral time constant of $0.1$ min is to be designed to control a process with transfer function$$G_{P}\left ( s \right )=\frac{10}{s^{2}+2s+100}$...
Milicevic3306
8.0k
points
asked
Mar 26, 2018
Instrumentation and Process Control
gate2016
numerical-answers
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2016 | Question: 53
For a unit step input, the response of a second order system is$$y\left ( t \right )=K_{p} \left [ 1-\frac{1}{\sqrt{1-\zeta ^{2}}} e^{\frac{\zeta t}{\tau }}\sin\left ( \f...
Milicevic3306
8.0k
points
asked
Mar 26, 2018
Instrumentation and Process Control
gate2016
instrumentation-and-process-control
numerical-answers
+
–
0
0 votes
0
0 answers
GATE Chemical 2015 | Question: 30
Match the output signals as obtained from four measuring devices in response to a unit step change in the input signal.$\begin{array}{cc}\&\text{P. Gas chromatograph, wit...
Milicevic3306
8.0k
points
asked
Mar 26, 2018
Instrumentation and Process Control
gate2015
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2015 | Question: 31
The transfer function for the disturbance response in an open-loop process is given by $G_{d}^{open}(s)$. The corresponding transfer function for the disturbance response...
Milicevic3306
8.0k
points
asked
Mar 26, 2018
Instrumentation and Process Control
gate2015
instrumentation-and-process-control
analytical-aptitude
+
–
0
0 votes
0
0 answers
GATE Chemical 2015 | Question: 60
Which one of the following transfer functions, upon a unit step change in disturbance at $t=0$, will show a stable time domain response with a negative initial slope (i.e...
Milicevic3306
8.0k
points
asked
Mar 26, 2018
Instrumentation and Process Control
gate2015
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2015 | Question: 61
The block diagram for a process with feedback control for output deviation $h$ is shown in the figure below. All transfer functions are given with pre-factor of $s$ in mi...
Milicevic3306
8.0k
points
asked
Mar 26, 2018
Instrumentation and Process Control
gate2015
numerical-answers
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2014 | Question: 53
Consider the following block diagram for a closed-loop feedback control system A proportional controller is being used with $K_{c}=-4$. If a step change in distrubance of...
Milicevic3306
8.0k
points
asked
Mar 25, 2018
Instrumentation and Process Control
gate2014
numerical-answers
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2014 | Question: 52
A process with transfer function, $G_{p}=\frac{2}{s-1}$ is to be controlled by a feedback proportional controller with a gain $K_{c}$. If the transfer functions of all ot...
Milicevic3306
8.0k
points
asked
Mar 25, 2018
Instrumentation and Process Control
gate2014
instrumentation-and-process-control
control-systems
+
–
0
0 votes
0
0 answers
GATE Chemical 2014 | Question: 45
A step change of magnitude $2$ is introduced into a system having the following transfer function$$G\left ( s \right )=\frac{2}{s^{2}+2s+4}$$The percent overshoot is ____...
Milicevic3306
8.0k
points
asked
Mar 25, 2018
Instrumentation and Process Control
gate2014
numerical-answers
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2014 | Question: 46
Given below is a simplified block diagram of a feedforward control system.The transfer function of the process is $G_{p}=\frac{5}{s+1}$ and the disturbance transfer funct...
Milicevic3306
8.0k
points
asked
Mar 25, 2018
Instrumentation and Process Control
gate2014
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2014 | Question: 14
Assume that an ordinary mercury-in-glass thermometer follows first order dynamics with a time constant of $10\:s$. It is at a steady state temperature of $0^{\circ}C$. At...
Milicevic3306
8.0k
points
asked
Mar 25, 2018
Instrumentation and Process Control
gate2014
instrumentation-and-process-control
numerical-answers
+
–
0
0 votes
0
0 answers
GATE Chemical 2014 | Question: 10
A unit $IMPLUSE$ response of a first order system with time constant $\tau$ and steady state gain $K_{p}$ is given by $\frac{1}{K_{p}\tau }e^{t/\tau }$$K_{p}e^{-t/\tau}$...
Milicevic3306
8.0k
points
asked
Mar 25, 2018
Instrumentation and Process Control
gate2014
instrumentation-and-process-control
numerical-answers
+
–
0
0 votes
0
0 answers
GATE Chemical 2013 | Question: 55
For the computation of Ziegler-Nichols settings, the ultimate period (in s/cycle) and the ultimate gain are $\pi$ and $0.8$, respectively$4\pi$ and $0.8$, respectively$4\...
Milicevic3306
8.0k
points
asked
Mar 25, 2018
Instrumentation and Process Control
gate2013
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2013 | Question: 45
A control value, with a turndown ratio of 50, follows equal percentage characteristics. The flow rate of a liquid through the value at 40% stem positions is 1 m$^{3}$/h. ...
Milicevic3306
8.0k
points
asked
Mar 25, 2018
Instrumentation and Process Control
gate2013
numerical-answers
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2018 | Question: 45
For a closed-loop system, consider the following transfer functions:process $G_{p}\left ( s \right )$, controller $G_{c}\left ( s \right )$, measuring device $G_{m}\left ...
gatecse
3.4k
points
asked
Feb 20, 2018
Instrumentation and Process Control
gate2018
numerical-answers
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2018 | Question: 44
Consider the following transfer function:$$G\left ( s \right )=\frac{3}{\left ( 5s+1 \right )^{2}}$$where, the natural period of oscillation is in min. The amplitude rati...
gatecse
3.4k
points
asked
Feb 20, 2018
Instrumentation and Process Control
gate2018
numerical-answers
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2018 | Question: 32
Match the items in Column $A$ with the items in Column $B$$\begin{array}{|cl|cI|}\hline&\text{$Column\:A$} & \text{$Column\:A$} \\ \hline &\text{P. Pure dead-time} & \te...
gatecse
3.4k
points
asked
Feb 20, 2018
Instrumentation and Process Control
gate2018
instrumentation-and-process-control
+
–
0
0 votes
0
0 answers
GATE Chemical 2018 | Question: 18
A first-order process having a transfer function, $G_{p}=\frac{2}{7s+1}$ is controlled by a proportional controller with gain of $3.2$. The process time constant is in mi...
gatecse
3.4k
points
asked
Feb 20, 2018
Instrumentation and Process Control
gate2018
instrumentation-and-process-control
process-calculations-and-thermodynamics
+
–
Page:
« prev
1
2